Directory Traversal in ATEN eco DC (CVE‑2026‑126964) Enables Arbitrary File Deletion
What It Is — The Zero Day Initiative advisory ZDI‑26‑992 describes a directory‑traversal flaw in the JSON‑based management interface of ATEN’s eco DC power‑distribution controller. The vulnerable endpoint, fwDeletes.json, accepts a JSON payload that includes a file‑path parameter. The implementation fails to sanitize the supplied path before passing it to a system‑level file‑delete routine. An authenticated attacker who can reach the controller’s REST API can craft a payload such as {"path":"../../../../Windows/System32/drivers/etc/hosts"} and cause the underlying operating system to delete the targeted file with SYSTEM privileges.
The vulnerability is authenticated (requires a valid user account) but otherwise requires no special privileges beyond network access to the device’s management interface. The CVSS v3.1 base score is 5.5 (Moderate), with the vector AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H – indicating low confidentiality impact, low integrity impact, but high availability impact because file deletion can render the controller inoperable or disrupt downstream power‑distribution services.
ATEN released a fix in eco DC version 1.2.119. The advisory notes that the issue was reported on 2026‑08‑04, publicly disclosed on 2026‑11‑13, and the advisory was updated the same day. No public exploitation reports have been observed, but the presence of a remote‑access API on many data‑center networks makes the attack surface non‑trivial.
Affected Products — ATEN eco DC (all versions prior to 1.2.119).
Why It Matters for Trust & Control Assurance — The flaw tests the control objective of secure configuration and input validation: organizations must ensure that management interfaces enforce strict validation of user‑supplied data and that privileged operations are limited to authorized, auditable actions. Failure to do so undermines the “protect” function of most governance frameworks and erodes confidence in the integrity of critical infrastructure.
Recommended Actions
- Patch Immediately – Upgrade all eco DC units to version 1.2.119 or later.
- Restrict Network Access – Place the controller’s management API behind a firewall or zero‑trust segment; allow only authorized management hosts.
- Enforce Strong Authentication – Verify that multi‑factor authentication (MFA) is enabled for all accounts that can access the API.
- Validate Input at the Edge – Deploy a web‑application firewall (WAF) or API gateway that enforces path‑normalization rules for any JSON payloads targeting
fwDeletes.json. - Monitor for Deletion Events – Enable detailed logging of file‑system operations on the controller and forward logs to a SIEM for real‑time alerting on unexpected deletions.
- Document Remediation Evidence – Capture patch‑deployment records, configuration snapshots, and log‑retention policies as audit evidence for compliance reviews.