Home › Intelligence › Brief
VULNERABILITY BRIEF🟠 High Vulnerability

Critical Heap‑Based Buffer Overflow (CVE‑2026‑126978) Enables Remote Code Execution on Philips Hue Bridge

A network‑adjacent attacker can exploit a heap‑based buffer overflow in the Philips Hue Bridge’s HomeKit service to execute arbitrary code without authentication. The flaw underscores the need for rigorous firmware patch management and IoT segmentation to satisfy control‑assurance objectives.

LiveThreat™ Intelligence · 📅 November 17, 2026· 📰 zerodayinitiative.com
🟠
Severity
High
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
1 sector(s)
✅
Actions
2 recommended
📰
Source
zerodayinitiative.com

(Pwn2Own) Philips Hue Bridge hap_pair_setup_handler Heap‑Based Buffer Overflow – Remote Code Execution (CVE‑2026‑126978)

What It Is — The Zero Day Initiative (ZDI) advisory ZDI‑26‑963 reveals a critical heap‑based buffer overflow in the HomeKit Accessory Protocol (HAP) service of the Philips Hue Bridge. The flaw resides in the hap_pair_setup_handler routine that processes pairing requests on TCP port 8080. The handler fails to validate the length of the incoming data before copying it into a fixed‑size heap buffer, allowing an unauthenticated, network‑adjacent attacker to overwrite adjacent memory and execute arbitrary code with the privileges of the Hue Bridge process.

The vulnerability is assigned CVSS v3.1 base score 8.8 (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H), indicating a network‑adjacent attack vector, no authentication or user interaction required, and total compromise of confidentiality, integrity, and availability. The issue was reported to Philips on 28 July 2026, and a coordinated public advisory was released on 13 November 2026. Philips issued a firmware update (Bridge v2 software 1975170000) that patches the overflow.

Affected Products — Philips Hue Bridge (all firmware versions prior to 1975170000).

Why It Matters for Trust & Control Assurance — This flaw tests the control objective of maintaining secure, up‑to‑date configurations for network‑connected devices. Demonstrating a patched, auditable firmware baseline satisfies a single control that maps to many frameworks (e.g., NIST CSF 2.0, ISO 27001, SOC 2).

Recommended Actions —

  • Verify the firmware version of every Hue Bridge in your environment; upgrade any device running a version earlier than 1975170000.
  • Enable network segmentation for IoT devices and enforce strict inbound firewall rules on port 8080.
  • Capture firmware version evidence and update your configuration‑management inventory to demonstrate control compliance.

Source: ZDI advisory

📰 Original Source
http://www.zerodayinitiative.com/advisories/ZDI-26-963/ ↗

This LiveThreat Intelligence Brief is an independent analysis. Read the original reporting at the link above.