Home › Intelligence › Brief
VULNERABILITY BRIEF🟠 High Vulnerability

Authentication Bypass (CVE‑2026‑126977) in Philips Hue Bridge Lets Network‑Adjacent Attackers Gain Control

A network‑adjacent attacker can exploit CVE‑2026‑126977 to bypass authentication on Philips Hue Bridge devices, gaining full control of HomeKit‑linked lighting. The flaw underscores the need for robust device authentication controls and continuous monitoring of IoT assets for audit readiness.

LiveThreat™ Intelligence · 📅 November 17, 2026· 📰 zerodayinitiative.com
🟠
Severity
High
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
1 sector(s)
✅
Actions
2 recommended
📰
Source
zerodayinitiative.com

Authentication Bypass (CVE‑2026‑126977) in Philips Hue Bridge Lets Network‑Adjacent Attackers Gain Control

What It Is — The Zero Day Initiative advisory ZDI‑26‑962 (also catalogued as ZDI‑CAN‑28323) details a critical authentication‑bypass flaw in the Philips Hue Bridge HomeKit pairing service. The vulnerability lives in the HomeKit Authentication daemon that listens on TCP 8080. An attacker positioned on the same LAN can send a specially‑crafted pairing request that causes the bridge to accept a blank password, effectively skipping any credential check. No user interaction or prior authentication is required. The CVSS v3.1 base score is 8.1 (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N), indicating high impact on confidentiality and integrity of the device’s control plane. Philips released firmware 1.75.1975170000 (and later) that patches the issue; devices running earlier versions remain vulnerable.

Affected Products — Philips Hue Bridge (all firmware versions prior to 1.75.1975170000).

Why It Matters for Trust & Control Assurance — This flaw directly tests the control objective of enforcing strong authentication for device management. An unauthenticated attacker can commandeer lighting, potentially using the bridge as a foothold for broader network moves. Verisq’s ACCESS_CONTROLS capability helps organizations prove that authentication policies are enforced and continuously monitored across IoT assets.

Recommended Actions —

  • Immediately upgrade every Hue Bridge to firmware 1.75.1975170000 or later.
  • Segment IoT devices on a dedicated VLAN or subnet, limiting lateral movement from compromised workstations.
  • Deploy network‑based intrusion detection signatures that flag anomalous HomeKit pairing traffic on port 8080.
  • Enable logging of all pairing attempts and integrate those logs into a centralized SIEM for continuous audit evidence.
  • Review and document the authentication control for all smart‑home devices in your trust‑center inventory.

Source: Zero Day Initiative advisory ZDI‑26‑962

📰 Original Source
http://www.zerodayinitiative.com/advisories/ZDI-26-962/ ↗

This LiveThreat Intelligence Brief is an independent analysis. Read the original reporting at the link above.

From the Verisq platform · Trust Operations

Access is where most audits get tested.

Verisq AI Trust Operations maps incidents like this to your access controls and collects the evidence continuously, keeping your trust posture defensible.

See where you'd stand with Verisq AI Trust Operations →