Home › Intelligence › Brief
VULNERABILITY BRIEF🟠 High Vulnerability

Critical Authentication Bypass in United Chargers Grizzl‑E Smart 40A EV Charger Backend (CVE‑2026‑131809)

A network‑adjacent attacker can bypass authentication on United Chargers’ Grizzl‑E Smart 40A EV chargers, enabling arbitrary code execution. The flaw highlights gaps in access‑control assurance for critical energy infrastructure.

LiveThreat™ Intelligence · 📅 November 23, 2026· 📰 zerodayinitiative.com
🟠
Severity
High
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
1 sector(s)
✅
Actions
4 recommended
📰
Source
zerodayinitiative.com

Critical Authentication Bypass in United Chargers Grizzl‑E Smart 40A EV Charger Backend (CVE‑2026‑131809)

What It Is — The Zero Day Initiative (ZDI) disclosed a new vulnerability (CVE‑2026‑131809) affecting United Chargers’ Grizzl‑E Smart 40A electric‑vehicle (EV) charging station. The flaw resides in the Open Charge Point Protocol (OCPP) backend configuration interface. An attacker positioned on the same network segment as the charger can issue configuration requests without any authentication, bypassing the intended access control. The CVSS v3.1 base score is 7.6 (High) with vector AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L. Exploitation grants the ability to manipulate charger settings and, when chained with other weaknesses, to execute arbitrary code in the device’s context.

The vulnerability was discovered during the Pwn2Own Automotive 2026 competition. Researchers from Compass Security demonstrated the bypass and reported it to United Chargers on 2026‑11‑06. The vendor did not acknowledge any of the outreach attempts, and ZDI proceeded with a coordinated public release on 2026‑11‑18. No public evidence of active exploitation has been observed, but the unauthenticated access path makes the charger a low‑hanging fruit for adversaries seeking to disrupt charging infrastructure or pivot to downstream networks.

Affected Products — United Chargers Grizzl‑E Smart 40A EV charging stations (all firmware versions disclosed in the advisory).

Why It Matters for Trust & Control Assurance — This issue directly tests the authentication and authorization controls that protect device management interfaces. Weak or missing authentication undermines the “Access Control” control objective that underpins many compliance frameworks (e.g., NIST CSF 2.0, ISO 27001). Demonstrating robust identity verification for backend services is a core trust signal for operators of critical energy infrastructure.

Recommended Actions

  • Isolate the affected chargers on a segmented VLAN or firewall rule that blocks inbound traffic from untrusted networks.
  • Inventory all deployed Grizzl‑E Smart 40A units and verify firmware versions against the vendor’s advisory.
  • Apply any available firmware patches once United Chargers releases them; until then, enforce network‑level access controls (ACLs, zero‑trust micro‑segmentation).
  • Document the mitigation steps and map them to the “Authentication and Authorization” control area for audit evidence.
  • Engage United Chargers through formal supply‑chain risk channels to obtain a remediation timeline and request a security‑by‑design roadmap.

Source: Zero Day Initiative Advisory – ZDI‑26‑1037

📰 Original Source
http://www.zerodayinitiative.com/advisories/ZDI-26-1037/ ↗

This LiveThreat Intelligence Brief is an independent analysis. Read the original reporting at the link above.

From the Verisq platform · Trust Operations

Could you prove your access controls held up here?

Credential and access failures map directly to identity and access-control requirements in every major framework. The Verisq AI Trust Operations platform shows where your evidence is thin before an auditor — or an attacker — finds out.

Explore the Verisq AI Trust Operations platform →