Home › Intelligence › Brief
VULNERABILITY BRIEF🟠 High Vulnerability

Zero‑Day Remote Code Execution (CVE‑2026‑131810) in United Chargers Grizzl‑E Smart 40A EV Charger Firmware

ZDI disclosed CVE‑2026‑131810, a remote‑code‑execution flaw in United Chargers’ Grizzl‑E Smart 40A EV charger that bypasses firmware integrity checks. The vulnerability allows unauthenticated network‑adjacent attackers to install arbitrary code, exposing charging infrastructure to control loss and data exposure. It underscores the need for robust software‑integrity controls to satisfy audit and compliance expectations.

LiveThreat™ Intelligence · 📅 November 23, 2026· 📰 zerodayinitiative.com
🟠
Severity
High
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
1 sector(s)
✅
Actions
4 recommended
📰
Source
zerodayinitiative.com

Zero‑Day Remote Code Execution (CVE‑2026‑131810) in United Chargers Grizzl‑E Smart 40A EV Charger Firmware

What It Is — The Zero Day Initiative (ZDI) disclosed a critical remote‑code‑execution flaw (CVE‑2026‑131810) in United Chargers’ Grizzl‑E Smart 40A electric‑vehicle (EV) charging station. The vulnerability lives in the charger’s implementation of the Open Charge Point Protocol (OCPP) message handling. When a charger receives an OCPP command that contains a firmware payload, the device fails to verify the payload’s cryptographic signature or hash before installing it. An unauthenticated, network‑adjacent attacker can therefore upload malicious code and execute it with full system privileges. The CVSS v3.1 base score is 7.5 (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H), indicating high confidentiality, integrity, and availability impact. No vendor patch exists; United Chargers has not responded to ZDI’s disclosure attempts despite multiple contacts since 14 April 2026.

Affected Products — United Chargers Grizzl‑E Smart 40A EV charging stations (all firmware versions released to date).

Why It Matters for Trust & Control Assurance — The flaw highlights the need for a software‑integrity control that validates firmware before installation, a control objective that satisfies multiple frameworks (e.g., NIST CSF 2.0, ISO 27001).

Recommended Actions — 1) Isolate the chargers from untrusted networks until a fix is available. 2) Enforce strict network segmentation and firewall rules that block inbound OCPP traffic from unknown sources. 3) Deploy a temporary integrity‑checking gateway that validates firmware signatures before they reach the device. 4) Document the control gap and collect evidence of the mitigation steps for audit readiness. Source: ZDI advisory


Technical Deep‑Dive

Vulnerability Origin – The Grizzl‑E Smart 40A uses OCPP 1.6 to receive firmware updates over the air. ZDI’s analysis shows that the charger parses the incoming OCPP “UpdateFirmware” message but never checks the hash or digital signature fields. The code path directly writes the payload to flash memory and triggers a reboot, effectively handing the attacker full code execution rights. Because the OCPP channel is typically exposed to the utility’s backend management system, an attacker positioned on the same LAN segment (e.g., a compromised IoT device or a rogue Wi‑Fi hotspot) can reach the charger without any authentication.

Exploitation Flow –

  • Reconnaissance – The attacker scans the local subnet for devices responding on the OCPP TCP port (default 4222).
  • Payload Delivery – Using a crafted OCPP UpdateFirmware request, the attacker embeds a malicious ELF binary as the firmware image.
  • Installation – The charger accepts the payload, writes it to its internal flash, and reboots into the attacker‑supplied code.
  • Post‑Compromise – The malicious firmware can open a reverse shell, exfiltrate network traffic, or act as a pivot point to other OT assets (e.g., load‑balancing controllers, billing servers).

Impact Scope – Successful exploitation grants full control of the charger, enabling the attacker to manipulate charging sessions, disrupt power delivery, or harvest usage data. While no public incidents of data theft have been reported, the potential for service disruption and privacy violations is significant, especially in fleet‑charging deployments where dozens of units share a common network.

Discovery & Disclosure Timeline – The vulnerability was first demonstrated at the Pwn2Own Automotive 2026 competition, where the research team from SK Shieldus successfully executed the exploit on a live unit. ZDI assigned advisory IDs ZDI‑26‑1035 and ZDI‑CAN‑28957, and attempted to contact United Chargers on 14 April 2026. After a month of silence, ZDI publicly released the advisory on 18 November 2026, updating it the same day with additional technical details.

Vendor Response – United Chargers has not issued a statement, nor have they provided a firmware update or mitigation guidance. ZDI’s advisory lists “restrict interaction with the product” as the only immediate mitigation, effectively recommending network isolation.

Industry Reaction – Security analysts note that the lack of firmware integrity checks is a common weakness in many IoT and OT devices, often stemming from cost‑driven design decisions. The U.S. Department of Energy has previously warned that compromised EV chargers could be leveraged to affect grid stability. Experts also point out that the vulnerability aligns with the “Secure Software Development” control objective, which many frameworks treat as a foundational element of a resilient supply chain.

Open Questions –

  • Will United Chargers release a signed firmware update, and if so, on what timeline?
  • Are there other United Chargers models sharing the same OCPP handling code?
  • How many installations are currently exposed on unsegmented networks?

Mitigation Guidance – Until a vendor patch arrives, organizations should:

  • Network‑segment chargers into a dedicated VLAN with no inbound access from guest or corporate networks.
  • Block OCPP ports at the perimeter and allow only whitelisted management IPs.
  • Deploy an external OCPP proxy that validates firmware signatures before forwarding updates.
  • Document the control gap in your risk register and capture screenshots of firewall rules, VLAN configurations, and proxy logs as audit evidence.

Control‑Assurance Takeaway

The Grizzl‑E Smart 40A case tests the software‑integrity control—ensuring that only verified firmware can be installed on critical OT assets. Demonstrating this control satisfies a single VCF objective that maps to NIST CSF 2.0’s “Protect” function and to multiple industry standards, providing a reusable trust signal across audits.

📰 Original Source
http://www.zerodayinitiative.com/advisories/ZDI-26-1035/ ↗

This LiveThreat Intelligence Brief is an independent analysis. Read the original reporting at the link above.

From the Verisq platform · Trust Operations

Every gap like this maps to a control you can evidence.

The Verisq AI Trust Operations platform maps incidents to your control framework and collects the evidence continuously — so your Trust Center shows proof, not promises, when a buyer or auditor asks.