Hard‑Coded OCPP Credentials Enable Auth Bypass in United Chargers Grizzl‑E Smart 40A EV Charger (CVE‑2026‑131811)
What It Is — The Zero Day Initiative (ZDI) disclosed a critical authentication‑bypass flaw in United Chargers’ Grizzl‑E Smart 40A electric‑vehicle (EV) charging station (CVE‑2026‑131811). The vulnerability resides in the OCPP (Open Charge Point Protocol) backend configuration interface, where the firmware ships with hard‑coded credentials. Because the credentials are embedded in the device and never required to be changed, any network‑adjacent attacker can connect to the charger’s management port, present the default secret, and gain full administrative access without any further authentication.
The flaw scores a CVSS v3.1 base rating of 7.6 (High) with the vector AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L. Exploitation does not require user interaction; a remote actor on the same LAN (or any reachable network segment) can issue OCPP commands that the charger accepts as if they originated from a legitimate operator console. Once authenticated, the attacker can modify charging parameters, disable safety limits, or, in combination with other vulnerabilities, execute arbitrary code in the device’s operating environment.
ZDI first reported the issue to United Chargers on 2026‑11‑06 and attempted repeated follow‑up to establish a coordinated disclosure channel. The vendor did not respond before the public advisory was released on 2026‑11‑18, and the advisory was updated the same day with additional technical details. The lack of vendor engagement means that no official patch or firmware update is currently available.
Affected Products — United Chargers Grizzl‑E Smart 40A EV charging stations (all firmware versions shipped to date).
Why It Matters for Trust & Control Assurance — This defect directly violates the control objective of robust authentication and credential management. Organizations that deploy these chargers must be able to demonstrate that default or hard‑coded secrets are eliminated and that access to critical device functions is auditable. Capability focus: ACCESS_CONTROLS.
Recommended Actions
- Isolate the chargers on a segmented network with strict inbound/outbound firewall rules, limiting access to trusted management stations only.
- Inventory all deployed Grizzl‑E Smart 40A units and verify whether they are reachable from any untrusted network segment.
- Apply compensating controls such as network‑level authentication (VPN, IP‑allow lists) and intrusion‑detection signatures that flag OCPP traffic using the known default credentials.
- Document the presence of hard‑coded credentials as a control gap and capture evidence for audit purposes.
- Engage the vendor formally (via legal or procurement channels) to demand a firmware update that removes the hard‑coded secrets.
- Monitor for anomalous OCPP commands or configuration changes using a SIEM or dedicated EV‑charging telemetry solution.