Home › Intelligence › Brief
VULNERABILITY BRIEF🟡 Medium Vulnerability

Authenticated Local DLL Search‑Path Flaw (CVE‑2026‑110936) Allows Code Execution in Siemens Software Center

CISA reports that Siemens Software Center versions before 4.0.9.8 load DLLs from an uncontrolled search path, enabling an authenticated local attacker to execute arbitrary code. The vulnerability (CVE‑2026‑110936, CVSS 6.7) underscores the importance of configuration‑management controls for audit readiness.

LiveThreat™ Intelligence · 📅 November 20, 2026· 📰 cisa.gov
🟡
Severity
Medium
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
2 sector(s)
✅
Actions
3 recommended
📰
Source
cisa.gov

Authenticated Local DLL Search‑Path Flaw (CVE‑2026‑110936) Enables Arbitrary Code Execution in Siemens Software Center

What It Is — The Cybersecurity and Infrastructure Security Agency (CISA) has issued an advisory (ICS‑A‑26‑295‑03) describing a vulnerability in Siemens Software Center versions earlier than 4.0.9.8. The application loads Dynamic‑Link Libraries (DLLs) from a search path that is not sufficiently constrained. An attacker who has already obtained a valid user account on the host can place a maliciously crafted DLL in a directory that the application scans, causing the software to load the rogue library. This results in arbitrary code execution with the same privileges as the compromised Siemens Software Center process. The flaw is catalogued as CVE‑2026‑110936 and carries a CVSS v3.1 base score of 6.7 (Medium).

Affected Products — Siemens Software Center < 4.0.9.8 (all editions).

Why It Matters for Trust & Control Assurance — The issue highlights the need for rigorous configuration‑management controls that enforce trusted library paths and prevent unauthorized code from being introduced into critical industrial‑control applications. Verisq’s Control Mapping capability can help organizations demonstrate continuous evidence that such configuration controls are in place across multiple compliance frameworks.

Recommended Actions —

  • Patch Immediately – Deploy Siemens’ released update (version 4.0.9.8 or later) to all affected endpoints.
  • Validate Versions – Inventory all installations of Siemens Software Center and confirm they meet the minimum version requirement.
  • Restrict DLL Search Paths – Configure the application to load libraries only from vetted directories; remove write permissions for non‑administrative users on those paths.
  • Implement Application Whitelisting – Use allow‑list policies (e.g., Windows AppLocker or similar) to block execution of unsigned DLLs in the Software Center’s search locations.
  • Monitor for Indicators of Compromise – Enable logging of DLL load events and set alerts for unexpected files appearing in the search path.
  • Review Access Controls – Ensure that only authorized personnel have local accounts on systems running the Software Center, and enforce strong authentication.

Source: CISA Advisory – ICSA‑26‑295‑03

📰 Original Source
https://www.cisa.gov/news-events/ics-advisories/icsa-26-295-03 ↗

This LiveThreat Intelligence Brief is an independent analysis. Read the original reporting at the link above.