Multiple High‑Severity Web Server Flaws in Siemens SIMATIC S7‑1500 PLCs Enable Unauthorized PLC Operations

CISA has identified eight critical vulnerabilities (CVE‑2026‑63350‑57) in the web server of Siemens SIMATIC S7‑1500 PLCs. The flaws allow malicious JavaScript execution in a legitimate user's browser session, potentially granting attackers the ability to manipulate PLC processes. Organizations must treat this as a control‑access risk and verify mitigation steps to maintain audit readiness.

LiveThreat™ Intelligence · 📅 November 20, 2026· 📰 cisa.gov
🟠
Severity
High
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
3 sector(s)
✅
Actions
4 recommended
📰
Source
cisa.gov

Multiple High‑Severity Web Server Flaws in Siemens SIMATIC S7‑1500 PLCs Enable Unauthorized PLC Operations

What It Is — The Cybersecurity and Infrastructure Security Agency (CISA) issued advisory ICSA‑26‑295‑14 reporting eight newly disclosed vulnerabilities (CVE‑2026‑63350 through CVE‑2026‑63357) in the embedded web server of Siemens SIMATIC S7‑1500 series programmable logic controllers (PLCs). The flaws span cross‑site scripting, insecure deserialization, and improper input validation. An attacker who can lure a legitimate user to a crafted web page can execute arbitrary JavaScript in that user’s browser session. Because the web server runs within the PLC’s control domain, the malicious script can issue valid PLC commands that the user’s session is authorized to perform, effectively allowing the attacker to manipulate process control functions without needing separate credentials.

Affected Products — All firmware revisions of the following Siemens devices are listed as vulnerable:

  • SIMATIC Drive Controller CPU 1504D TF (6ES7615‑4DF10‑0AB0)
  • SIMATIC Drive Controller CPU 1507D TF (6ES7615‑7DF10‑0AB0)
  • SIMATIC ET 200SP CPU 1510SP F‑1 PN (6ES7510‑1SJ01‑0AB0)
  • SIMATIC ET 200SP CPU 1510SP F‑1 PN (6ES7510‑1SK03‑0AB0)
  • SIMATIC ET 200SP CPU 1510SP‑1 PN (6ES7510‑1DJ01‑0AB0)

…and any other S7‑1500 models that include the same web‑server component (versions “all/*”).

Why It Matters for Trust & Control Assurance — The vulnerabilities expose a gap in access‑control enforcement: a user‑authorized web session can be hijacked to perform PLC actions beyond the attacker’s intent. This directly tests the control objective of ensuring that only properly authenticated and authorized identities can execute critical control commands, a cornerstone of NIST CSF 2.0’s Protect function.

Recommended Actions —

  • Inventory all deployed S7‑1500 PLCs and verify firmware versions against the affected list.
  • Apply Siemens patches as soon as they are released; for devices without immediate patches, enable the vendor‑recommended mitigations (e.g., disable the web server, restrict network access to trusted subnets, enforce TLS 1.2+).
  • Review and tighten web‑interface access controls – enforce least‑privilege roles, require multi‑factor authentication for web access, and segment PLC networks from corporate IT zones.
  • Enable comprehensive logging of web‑server requests and PLC command execution; forward logs to a SIEM for anomaly detection.
  • Conduct a penetration test focused on web‑interface abuse to validate that mitigations are effective.

Source: CISA Advisory ICSA‑26‑295‑14

📰 Original Source
https://www.cisa.gov/news-events/ics-advisories/icsa-26-295-14 ↗

This LiveThreat Intelligence Brief is an independent analysis. Read the original reporting at the link above.

From the Verisq platform · Trust Operations

Could you prove your access controls held up here?

Credential and access failures map directly to identity and access-control requirements in every major framework. The Verisq AI Trust Operations platform shows where your evidence is thin before an auditor — or an attacker — finds out.

Explore the Verisq AI Trust Operations platform →