Critical SQLite Flaws (CVE‑2025‑6965, CVE‑2025‑70873, CVE‑2025‑71316, CVE‑2026‑11822, CVE‑2026‑11824) in Siemens RUGGEDCOM CROSSBOW Station Access Controller

Siemens reports five CVEs affecting the embedded SQLite component of its RUGGEDCOM CROSSBOW Station Access Controller (SAC) with a CVSS score of 9.8. The vulnerabilities allow memory corruption, data exposure, and remote code execution, threatening critical‑infrastructure deployments worldwide. Organizations must prove they have a robust vulnerability‑management process to stay audit‑ready.

LiveThreat™ Intelligence · 📅 November 20, 2026· 📰 cisa.gov
🔴
Severity
Critical
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
2 sector(s)
✅
Actions
5 recommended
📰
Source
cisa.gov

Multiple Critical SQLite Flaws (CVE‑2025‑6965, CVE‑2025‑70873, CVE‑2025‑71316, CVE‑2026‑11822, CVE‑2026‑11824) in Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC)

What It Is — The Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) embeds an SQLite database library that, in versions prior to 6.0, contains four distinct vulnerabilities:

  • CVE‑2025‑6965 – Numeric truncation error that can cause memory corruption when aggregate terms exceed column limits.
  • CVE‑2025‑70873 – Improper clearing of heap memory before release (a “heap inspection” issue) that may expose residual data to an attacker.
  • CVE‑2025‑71316 – Improper handling of Unicode encoding, allowing crafted input to trigger out‑of‑bounds reads.
  • CVE‑2026‑11822 and CVE‑2026‑11824 – Heap‑based buffer overflow conditions that can be leveraged for arbitrary code execution.

All five CVEs share a CVSS v3.1 base score of 9.8 (Critical), indicating a high likelihood of remote exploitation with severe impact, including full device takeover, denial‑of‑service, or disclosure of sensitive configuration data. The vulnerable component is part of the device’s internal management interface, which is reachable by operators and, in some deployments, by remote maintenance tools.

The advisory notes that the affected devices are deployed worldwide across critical manufacturing, transportation, energy, healthcare, financial services, and government sectors. Siemens has issued a firmware update that upgrades the embedded SQLite library to a patched version and recommends that all installations upgrade to the latest SAC release (≥ 6.0) immediately.

Affected Products — Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) versions < 6.0.

Why It Matters for Trust & Control Assurance — These flaws test the vulnerability‑management control objective: organizations must maintain an up‑to‑date inventory of software components, monitor for high‑severity advisories, and apply patches promptly. Failure to do so leaves a single unpatched library as a gateway to compromise of industrial control environments.

Recommended Actions —

  • Inventory every CROSSBOW SAC unit and record the firmware version.
  • Apply Siemens’ latest firmware (≥ 6.0) without delay.
  • Integrate SQLite library version checks into your continuous vulnerability‑scanning pipeline.
  • Document patch deployment in a centralized evidence store (e.g., Verisq Trust Center) to support audit readiness.
  • Review network segmentation and remote‑access controls to limit exposure of the SAC management interface.

Source: CISA Advisory – ICSA‑26‑295‑15

📰 Original Source
https://www.cisa.gov/news-events/ics-advisories/icsa-26-295-15 ↗

This LiveThreat Intelligence Brief is an independent analysis. Read the original reporting at the link above.

From the Verisq platform · Trust Operations

Misconfigurations are control gaps in disguise.

Verisq AI Trust Operations turns findings like this into mapped controls with continuous evidence, keeping your audit readiness current instead of point-in-time.