Home › Intelligence › Brief
VULNERABILITY BRIEF🟠 High Vulnerability

Path‑Traversal and Info‑Leak Flaws (CVE‑2026‑85114, CVE‑2026‑85115) in Siemens .NET Client Library for SIMATIC S7 Webserver API

CISA reports two high‑severity vulnerabilities in Siemens' .NET client library that allow path‑traversal file writes and leakage of internal error details. The flaws affect versions < 3.3.61/3.3.62 and can be mitigated by upgrading to the patched release. This highlights the need for robust input validation and file‑system access controls across compliance frameworks.

LiveThreat™ Intelligence · 📅 November 18, 2026· 📰 cisa.gov
🟠
Severity
High
VU
Type
Vulnerability
🎯
Confidence
High
🏢
Affected
1 sector(s)
✅
Actions
5 recommended
📰
Source
cisa.gov

Siemens .NET Client Library for SIMATIC S7 Webserver API – Path‑Traversal & Information‑Leak Vulnerabilities (CVE‑2026‑85114, CVE‑2026‑85115)

What It Is — The U.S. Cybersecurity & Infrastructure Security Agency (CISA) issued an advisory (ICS‑A‑26‑321‑02) reporting two high‑severity flaws in Siemens’ .NET Client Library for the SIMATIC S7 Webserver API. Both CVEs carry a CVSS v3 base score of 7.5 (High).

  • CVE‑2026‑85114 – Improper limitation of a pathname to a restricted directory (path‑traversal). The library fails to validate filenames received from a remote S7 webserver during ticket‑download operations. An attacker who can manipulate the ticket response can cause the client to write files outside the intended download folder, potentially overwriting legitimate files if the client is configured to allow overwrites.
  • CVE‑2026‑85115 – Generation of error messages containing sensitive information. When the library encounters malformed input, it may return detailed stack traces or internal configuration data to the calling application, exposing operational details that could aid further exploitation.

Both flaws reside in versions < 3.3.61 and < 3.3.62 of the library. Siemens has published a patched release (≥ 3.3.62) and strongly recommends all users upgrade immediately.

Affected Products — Siemens .NET Client Library for SIMATIC S7 Webserver API (versions < 3.3.61 and < 3.3.62).

Why It Matters for Trust & Control Assurance — The vulnerabilities expose a gap in input validation and file‑system access controls, a control objective that underpins many compliance frameworks (e.g., NIST CSF 2.0). Verisq’s Control‑Mapping capability can help you map this gap to concrete evidence across your control inventory.

Recommended Actions

  • Patch Immediately – Deploy Siemens .NET Client Library ≥ 3.3.62 on all affected systems.
  • Validate Input – Review any custom code that consumes the library for additional filename sanitization.
  • Restrict File Permissions – Ensure the download directory is isolated with least‑privilege ACLs; disable overwrite where possible.
  • Monitor Logs – Enable detailed logging of file‑write operations and error messages; alert on anomalous paths.
  • Map to Controls – Use a control‑mapping tool to record the remediation steps against the “input validation” and “file‑system protection” objectives in your framework of record.

Source: CISA Advisory – ICSA‑26‑321‑02

📰 Original Source
https://www.cisa.gov/news-events/ics-advisories/icsa-26-321-02 ↗

This LiveThreat Intelligence Brief is an independent analysis. Read the original reporting at the link above.

From the Verisq platform · Trust Operations

Every gap like this maps to a control you can evidence.

The Verisq AI Trust Operations platform maps incidents to your control framework and collects the evidence continuously — so your Trust Center shows proof, not promises, when a buyer or auditor asks.

Explore the Verisq AI Trust Operations platform →