Millions of Intelbras IP Cameras at Risk: Unauthenticated Firmware‑Upgrade DoS Vulnerability (CAN‑2026‑2035970, CVSS 4.0 5.1)
What It Is — Researchers at Kaspersky’s SecureList discovered a denial‑of‑service (DoS) flaw in Intelbras‑branded IP surveillance cameras. The vulnerability lives in the firmware‑upgrade endpoint http://<ip_address>/firmwareUpgrade_service/Demo, which can be reached over the local network without any authentication check. An attacker who can join the same Wi‑Fi network can send a single HTTP POST request containing any file; the camera immediately initiates a firmware‑upgrade routine, reboots, and goes offline for about a minute. Repeating the request keeps the device offline indefinitely, effectively denying legitimate users access to live video and management functions.
The issue was reported to Intelbras, who coordinated with the OEM and released a patched firmware (version R.260804) that now validates session cookies and requires an authenticated session before accepting an upgrade request. The vulnerability has been assigned a candidate ID CAN‑2026‑2035970 by MITRE and is awaiting a CVE number. Intelbras’ own advisory rates the flaw as Medium (CVSS 4.0 5.1). The original firmware (v240927) affected a family of models—including iM3B‑C, iMX C, iM4 C, iM5 SC, iME 360 C, and iM7+ FC—representing millions of devices deployed via the Intelbras Mibo Smart app (over 4 million downloads, primarily in Brazil and several South‑American markets).
Affected Products — Intelbras IP cameras across the iM3B‑C, iMX C, iM4 C, iM5 SC, iME 360 C, and iM7+ FC lines, running firmware v240927 (or earlier) and upgraded via the unauthenticated endpoint.
Why It Matters for Trust & Control Assurance — The flaw tests the availability control objective: ensuring that critical monitoring services remain operational and are not easily taken offline. Verisq’s Control Mapping capability can help you prove that firmware‑upgrade processes are protected and auditable across your IoT fleet.
Recommended Actions
- Inventory all Intelbras cameras and verify the installed firmware version.
- Upgrade any device running firmware v240927 or earlier to the patched version R.260804 using the official Intelbras update procedure.
- Segment camera networks from general Wi‑Fi or enforce strict VLAN isolation to limit lateral access.
- Monitor for unexpected reboot events or firmware‑upgrade traffic on the network; log and correlate these events with your SIEM.
- Document the remediation steps and retain firmware version evidence for audit purposes.